Product: 3092A ControlBusTM, Coax RG6, #18 Sol BCCS, PO Ins, QUAD AL Shld, PVC Jkt, CMR Product Description ControlBusTM, Coax RG6 18AWG (Solid) Bare Copper Covered Steel, PO Insulation, Overall Duofoil(R)+ Aluminum Braid(60%)+Overall Duofoil(R)+Aluminum Braid(40%) Shield, PVC Outer Jacket, CMR Technical Specifications Product Overview harsh environment, factory automation, ControlNetTM, Modbus II, Industrial Coax, Belden ControlNet cables provide maximum signal integrity and run length exceeding the high-speed, time-critical requirements necessary for ControlNet factory floor applications Suitable Applications: Physical Characteristics (Overall) Conductor AWG Stranding 18 Solid Material Nominal Diameter No. of Coax BCCS - Bare Copper Covered Steel 0.04 in Conductor Count: 1 1 Insulation Material Nominal Diameter PE - Polyethylene (Foam) 0.18 in Table Notes: Gas Injected Outer Shield Material Type Layer Material Material Trade Name Coverage [%] Tape 1 Alum / Poly / Alum Bonded Duofoil(R) 100% Braid 2 Aluminum 60% Tape 3 Alum / Poly / Alum Duofoil(R) 100% Braid 4 Aluminum 40% Outer Jacket Material Material Nominal Diameter PVC - Polyvinyl Chloride 0.298 in Electrical Characteristics Conductor DCR Nominal Conductor DCR Nominal Outer Shield DCR Outer Conductor DCR 28 Ohm/1000ft 3.6 Ohm/1000ft Capacitance Nom. Capacitance Conductor to Shield 16.2 pF/ft Inductance Nominal Inductance 0.097 H/ft 3.6 Ohm/1000ft Impedance Nominal Characteristic Impedance 75 Ohm Return Loss (RL) Frequency [MHz] Min. Structural Return Loss (SRL) 5 - 50 MHz 23 dB High Frequency (Nominal/Typical) Frequency [MHz] Nom. Insertion Loss 1 MHz 0.35 dB/100ft 2 MHz 0.38 dB/100ft 5 MHz 0.45 dB/100ft 10 MHz 0.59 dB/100ft 20 MHz 0.86 dB/100ft 50 MHz 1.37 dB/100ft 100 Mhz MHz 1.97 dB/100ft 200 Mhz MHz 2.82 dB/100ft 300 MHz MHz 3.48 dB/100ft 400 Mhz MHz 4.04 dB/100ft Delay Nominal Delay Nominal Velocity of Propagation (VP) [%] 1.22 ns/ft 83.0% High Freq Min. SRL (Structural Return Loss) 23 dB Voltage UL Voltage Rating 300 V RMS Temperature Range UL Temp Rating: 75C Operating Temp Range: -30C To +75C Mechanical Characteristics Bulk Cable Weight: 34 lbs/1000ft Max. Pull Tension: 117 lbs Min Bend Radius/Minor Axis: 3 in Standards NEC/(UL) Compliance: CMR, CL2R, CMG CEC/C(UL) Compliance: CMG CPR Euroclass: Eca Applicable Environmental and Other Programs EU Directive 2000/53/EC (ELV): Yes EU Directive 2003/96/EC (BFR): Yes EU Directive 2011/65/EU (ROHS II): Yes EU Directive 2012/19/EU (WEEE): Yes EU Directive 2015/863/EU: Yes EU Directive Compliance: EU Directive 2003/11/EC (BFR) EU CE Mark: Yes EU RoHS Compliance Date (yyyy-mm-dd): 2004-01-01 MII Order #39 (China RoHS): Yes Suitability Suitability - Aerial: Yes - When supported by messenger wire Suitability - Burial: No Suitability - Hazardous Locations: No Suitability - Indoor: Yes Suitability - Outdoor: Yes Suitability - Sunlight Resistance: Yes Flammability, LS0H, Toxicity Testing UL Flammability: UL 1666 Vertical Shaft IEC Flammability: IEC 60332-1-2 UL voltage rating: 300 V RMS Plenum/Non-Plenum Plenum (Y/N): No Plenum Number: 3093A Part Number Variants Putup Type Length 3092A 010500 Item # Black Color Reel 500 ft 612825141372 UPC 3092A 0101000 Black Reel 1,000 ft 612825141334 3092A 0102000 Black Reel 2,000 ft 612825141358 3092A 0105000 Black Reel 5,000 ft 612825141389 3092A 01010000 Black Reel 10,000 ft 612825141341 3092A X7E500 Blue X7E Reel 500 ft 612825141303 3092A X7E1000 Blue X7E Reel 1,000 ft 612825141280 3092A X7E5000 Blue X7E Reel 5,000 ft 612825141310 Footnote: C - CRATE REEL PUT-UP. History Update and Revision: Revision Number: 0.314 Revision Date: 04-28-2020 (c) 2020 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.